uniwire
Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.
First seen 13 Oct 2026. Evidence as of 13 Oct 2026.
14
Tools
From an anonymous probe
1
Source listings
Each with its own history
1
Recorded changes
Since first seen
Tools
| Tool | Description | Behaviour |
|---|---|---|
| apply_patch | Edit an electrical diagram by node id (change a rating, add a circuit, move a load...) and return the new document. ops (applied in order): {"op":"set","id":ID,"path":"in_A","value":20} (null value removes; no id = document root, e.g. path "installation.earthing"); {"op":"add","parent":ID,"node":{...},"index":0} (or "at":"sources"); {"op":"remove","id":ID}; {"op":"move","id":ID,"parent":ID,"index":0}; {"op":"rename","id":ID,"new_id":NEW}; {"op":"link","link":{"kind":"control","from":ID,"to":ID}}; {"op":"unlink","id":LINK_ID} or {"op":"unlink","from":ID,"to":ID,"kind":K}. On failure returns ok=false and errors naming the failing op index (null = validation of the result). | Read-only |
| bom | Bill of materials of an electrical installation (nomenclature), grouped by manufacturer / part number (nodes with a product reference). | Read-only |
| check | Check an electrical installation (single-line diagram, panel, schéma unifilaire, tableau électrique): validates the document, then applies the rule profiles (NF C 15-100 'nfc15100', IEC 60364 'iec60364', PLC; default: the document's 'profiles'; 'core' always applies): breaker ratings against cable sections, RCDs, circuits per protection, selectivity... Returns findings (level error/warning/info, rule, node id, message, source), a summary, viewer_url (opens the document in the uniwire web editor: drawing, findings, downloads) and pdf_url (same, and downloads the PDF drawn by uniwire). Give both to the user as clickable links. 'scope' says what the checks cover: tell the user once that they are not a conformity certificate. | Read-only |
| describe | Text outline of an electrical diagram: installation, full tree of the panel with stable ids, ratings and cables, links, interlocks, boards and findings summary. Use it to review a document or find the ids for apply_patch. | Read-only |
| get_example | Return an example installation document by name (or number prefix, e.g. '02'), to adapt to the user's project. | Read-only |
| get_reference_card | Reference card of the uniwire format for electrical diagrams: document skeleton, node types (breakers, RCDs, cables, loads, transformers, PV...) and fields, enums, links, pitfalls, examples. Read it before writing a document. level: 'compact' (~3k tokens) or 'full'; lang: 'en' or 'fr'. | Read-only |
| list_examples | List the 52 example installations (dwellings, shops, offices, workshops, PV, EV charging, UPS, MV/LV substations, PLCs): name, title, language, profiles, earthing, system. Good starting points. | Read-only |
| list_types | List node types (type, category, label), optionally for one category: source, measure, protection, switching, control, converter, conductor, container, connector, load. | Read-only |
| normalize | Resolved document: templates applied, every id assigned, canonical numbers. | Read-only |
| render | Draw the electrical diagram (schéma unifilaire / multifilaire). kind: 'single-line' or 'multi-line'; view: a view id of the document (e.g. a wire-marking view). format 'svg' returns the SVG text of every sheet (or of 'sheet', numbered from 1); 'pdf' writes to 'path' if given, else returns base64 (requires the uniwire[pdf] extra); on the hosted server it returns pdf_url instead. To give the user the PDF, give them pdf_url as a clickable link. color: 'none' | 'conductors' | 'phase' | 'source' | 'status' | 'voltage' (adds a legend); conductor_colors: 'iec' (IEC 60445) | 'us'. | Read-only |
| type_info | All fields of a node type with descriptions and allowed values (enums). | Read-only |
| validate | Validate a uniwire document (electrical diagram as JSON: object, JSON text or file path) against the format. Returns valid + issues, each naming the node id and field when possible, plus viewer_url and pdf_url (links for the user). check does the same and also applies the electrical rules. | Read-only |
| viewer_link | Links for the user: viewer_url opens the document in the uniwire web editor (drawing, single-line and multi-line, rule findings, PDF and SVG downloads, nothing to install); pdf_url opens it and downloads the PDF drawn by uniwire. The document travels in the link (after '#') and is stored nowhere. Give them to the user as clickable Markdown links. | Read-only |
| wiring | Wiring exports of an installation as rows with stable column names (repérage des fils, carnet de câbles): what='markers' (one row per wire end, for label printers), 'wires' (wire list) or 'cables' (cable schedule). Marks follow the wire_marking rules of the view (id), by default the first view that declares them. | Read-only |
Change history
- Listed (registry)
| Source | Listing | First seen | Last seen | Versions |
|---|---|---|---|---|
| Official MCP Registry | io.github.uniwire-dev/uniwire | 13 Oct 2026 | 13 Oct 2026 | 1 |